MIL-DTL-38359E
TABLE II. Requirements cross-reference matrix.
Requirement
Verification
Requirement
Verification
4.4 Conformance inspection. Conformance inspection shall consist of group A and B inspections.
4.4.1 Inspection of product for delivery. Inspection of product for delivery shall consist of groups A
and B.
4.4.1.1 Selection of sample units. The inspection sample shall be product selected at random from
the lot without regard to quality and shall be of the size specified in table V. A sample unit is defined as a
length of cable drawn from a unit of product.
4.4.1.2 Test specimen. A test specimen may be the entire sample unit (length of finished cable) or
any portion of the sample unit that is to be tested.
4.4.2 Group A inspection. Each cable shall be subjected to the individual tests shown in table III.
TABLE III. Group A inspection.
Inspection
Requirement
Test method
Visual inspection
Inspection of product
High potential withstanding
voltage test
Insulation resistance test
Continuity test
4.4.3 Group A acceptance. Each sample selected in accordance with 4.4.1.1 shall be examined to
determine conformance with the requirements in table III. If one or more defects are found in the
inspection sample, the production lot shall be rejected and not supplied to this specification.
4.4.4 Group B inspection. Group B inspection shall consist of the tests specified in table IV, in the
order shown. Group B inspection shall be made on sample units selected from inspection lots which
have passed group A inspection. Sample size selection shall be in accordance with table VI (small
sample inspection).