MIL-DTL-28830/5E
ENGINEERING INFORMATION:
Weight:
Type II jacketing: 0.8 lb/ft, nominal.
Type IV jacketing: 1.15 lb/ft, nominal.
Minimum in-service bending diameter: 40 inches (1.02 meter).
Operating voltage: 5,600 V rms.
Average power rating: See figure 2.
Operating temperature: -50 C to +85 C
REQUIREMENTS:
Design and construction: See figure 1.
Flexibility and cold bend mandrel diameter:
40 inches (1.02 meter), maximum.
Test cable length: 30 feet (9.1 meters).
Impedance: 50 + 1 ohms.
Attenuation: See figure 2.
Velocity of propagation: 90% nominal .
Capacitance: 22.5 pf/ft, maximum.
Voltage standing wave ratio (VSWR): 1.70, maximum.
VSWR frequency range: 100 MHz to 2.4 GHz.
Dielectric withstanding voltage: 15,000 V dc
Jacket spark:
Type II jacketing: 10,000 V rms.
Type IV jacketing: 8,000 V rms.
Acid gas generation (type IV only): 2.0 maximum.
Halogen content (type IV only): 0.2 maximum.
Smoke index (type IV only): 35 maximum.
Toxicity index (type IV only): 5 maximum.
Tensile strength and elongation:
Type II jacketing: 2,100 psi and 700 percent elongation, minimum.
Type IV jacketing: 1,200 psi and 115 percent elongation, minimum.
Part or Identifying Number (PIN):
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business