MIL-DTL-27500H
TABLE IX. Test mandrel diameters.
Finished cable
Cold bend (4.3.5)
Finished cable
Thermal Shock
diameter (inches)
Crosslinked verification
diameter
(4.3.8 )
(4.3.10)
(inches)
Aging stability (4.3.9)
Blocking (4.3.13)
(inches)
(inches)
0 to 0.125
3
0 to 0.083
0.750
0.084 to 0.111
1.0
0.126 to 0.250
6
0.112 to 0.139
1.250
0.140 to 0.194
1.750
0.251 to 0.360
10
0.195 to 0.250
2.250
0.251 to 0.334
3.00
0.361 to 0.750
18
0.335 to 0.444
4
0.445 to 0.556
5
0.751 to 1.200
30
0.557 to 0.667
6
0.668 to 0.889
8
1.201 to 2.000
48
0.890 to 1.111
10
1.112 to 1.556
14
1.557 to 2.000
18
TABLE X. Specific gravity for jacketing materials.
Jacket Styles
Specific gravity
01,02, 03, 04,
1.4
05, 06, 07, 09, 16, 20, 21
2.2
08, 10
1.8
11, 12, 22
1.6
14, 15, 17, 18, 23
1.7
24
1.9
5.
PACKAGING
For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When actual
packaging of material is to be performed by DoD personnel, these personnel need to contact the responsible packaging activity to
ascertain requisite packaging requirements. Packaging requirements are maintained by the Inventory Control Point's packaging
activity within the Military Department or Defense Agency, or within the Military Department's System Command. Packaging data
retrieval is available from the managing Military Department's or Defense Agency's automated packaging files, CD-ROM products,
or by contacting the responsible packaging activity.