MIL-DTL-27072/76C
Design and construction:
See figure 1
Number of conductors:
10
105°C
Temperature rating:
Components:
Basic wire:
M16878/17BDB* (see table I)
Conductor:
Tinned copper
Primary insulation:
Polyvinyl chloride
Colors:
White
White with black tracer
White with brown tracer
White with red tracer
White with orange tracer
White with yellow tracer
White with green tracer
White with blue tracer
White with violet tracer
White with gray tracer
Jacket over insulation:
Polyamide
Color:
Natural
Filler:
Not applicable
Cabling:
Core:
Number of conductors:
2 (1 twisted pair)
Pitch or lay:
1.50 inches nominal
Shield Number 3:
Material:
Tinned copper
Gauge:
36 AWG
Braid angle:
20 to 40 degrees
First layer:
Number of conductors:
8
Pitch or lay:
3.0 inches nominal
Shield Number 2:
Material:
Tinned copper
Gauge:
36 AWG
Braid angle:
20 to 40 degrees
Binder tape material:
Polyester (over shield number 2)
Shield Number 1:
Material:
Tinned copper
Gauge:
36 AWG
Braid angle:
20 to 40 degrees
Jacket undershield:
Not applicable
2