MIL-DTL-2486E
4.4.2 Sampling. A random sample shall be selected from each lot as specified in table II.
TABLE II. Inspection sample.
Inspection lot
Sample size
size 1/
1
1
2 to 8
2
9 to 90
3
91 to 150
12
151 to 280
19
281 to 500
21
501 to 1,200
27
1,201 to 3,200
36
3,201 to 10,000
38
10,001 to 35,000
46
1/ Lot size is based on the number of
units of product
4.4.3 Rejected lot. Failure of any sample to pass any inspection shall constitute a failure of the lot. If
an inspection lot is rejected, the contractor may rework the lot to correct the defects or screen out the
defective units, and resubmit the lot for re-inspection. Such lots shall be separated from new lots and
shall be identified as re-inspected lots (see 4.4.4).
4.4.4 Noncompliance. If a sample fails to pass any inspection, the contractor shall notify the
cognizant inspection activity of such failure and take corrective action on the materials or processes or
both, as warranted on all units of the product. Acceptance and shipment of the product shall be
discontinued until corrective action has been taken. After the corrective action has been taken, the
conformance inspection shall be repeated on replacement articles. (This includes all tests and
examinations, or only the test that the original sample failed, at the option of the cognizant inspection
activity.) Final acceptance and shipment shall be withheld until inspection has shown that the corrective
action was successful. In the event of failure after re-inspection, information concerning the failure shall
be provided to the cognizant inspection activity.
4.4.5 Group A inspection. Group A inspection shall include the applicable inspections specified in
table I.
4.4.6 Group B inspection. Group B inspection shall include the applicable inspections specified in
table I. Unless otherwise specified (see 6.2), group B inspection shall be performed on sample units that
have been subjected to and have passed the group A inspection.
4.5 Methods of inspection.
4.5.1 Insulation color coding. Samples of the cable shall be examined as specified in 3.6.
4.5.2 Overall shield. Samples of the shielded cable shall be examined as specified in 3.9.
4.5.3 Shielded conductors. Samples of the insulated and shielded conductors shall be examined as
specified in 3.7.
4.5.4 Cabling. Sampling of the cabled conductors shall be examined as specified in 3.8.
6