MIL-DTL-24643C
CONDUCTOR PAIR PLUS SURROUNDING
SIGNAL
SHIELD WITHIN SPECIMEN, OR
GENERATOR
AN ADAPTER CONNECTOR, OR A
DIRECT CONNECTION, AS
SPECIFIED (SEE 4.8.1.3)
CALIBRATED
VARIABLE
DETECTOR
ATTENUATOR
FIXED
FIXED
ATTENUATOR
ATTENUATOR
IMPEDANCE-
IMPEDANCE-
MATCHING
MATCHING
TRANSFORMER
TRANSFORMER
FIGURE 16. Block diagram of electrical connections for the attenuation test when testing a conductor pair plus surrounding shield.
CONDUCTOR PAIR PLUS SURROUNDING
SHIELD WITHIN SPECIMEN
PULSE
GENERATOR
OUTPUT
INPUT
OSCILLOSCOPE
PULSE
PULSE
TRANSFORMER
TRANSFORMER
SIGNAL
SIGNAL
CHANNEL
CHANNEL
NO. ONE
NO. TWO
FIGURE 17. Block diagram of electrical connections for the pulse response test.