MIL-DTL-24643/8E
TABLE I. Details.
Number of
Insulated conductor
Overall diameter
Military part no.
Type and size
conductors
diameter min. (inch)
max. (inch)
M24643/8
-01UN
LSMMOP-5
5
0.065
0.305
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
27.96
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
1000
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
100
Conductor continuity
No failure
Group A:
Visual and dimensional
No failure
Group B:
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Twisting and bending endurance
At 75 °C, cycles, min.
6000
At minus 30±2 °C (cycles, min.)
2000
Roller diameter (inches, max.)
1.5
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
Tensile strength (lb/in2, min.)
1300
Elongation (percent, min.)
160
Tear (lb/in thickness, min.)
35
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business