MIL-DTL-24643/58F
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
42.17
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
2000
Conductor to overall shield
1000
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
500
Conductor to overall shield
500
Overall shield to overall shield
100
Conductor continuity
No failure
Shield continuity
No failure
Jacket flaws
No failure
Group A:
Visual and dimensional
No failure
Characteristic impedance, at 1 megahertz (MHz) (ohms)
135±15
Group B:
Cold bending cable
No failure
Bending endurance
At 25 °C (cycles, min.)
25
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
Tensile strength (lb/in2, min.)
1300
Elongation (percent, min.)
160
Tear (lb/in thickness, min.)
35
3