MIL-DTL-24643/52F
TABLE I. Details.
Overall diameter
Cable jacket
Military part no.
Number of
thickness min.
Type and size
min.
max.
M24643/52
pairs
avg. (inch)
(inch)
(inch)
1½ 1/
-01UN
LSTPNW-1½
0.040
0.217
0.235
-02UN
LSTPNW-3
3
0.040
0.287
0.310
-03UN
LSTPNW-5
5
0.040
0.338
0.365
-04UN
LSTPNW-10
10
0.040
0.435
0.470
-05UN
LSTPNW-15
15
0.040
0.490
0.530
-06UN
LSTPNW-20
20
0.040
0.532
0.575
-07UN
LSTPNW-30
30
0.050
0.629
0.680
-08UN
LSTPNW-40
40
0.050
0.708
0.765
NOTE:
1/
Size 1½ is composed of three conductors cabled to form a triad.
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
17.94
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
2000
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
1000
Conductor continuity
No failure
Group A:
Visual and dimensional
No failure
Group B:
Cold bending cable
No failure
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Physicals (unaged)
Insulation (extruded)
Insulation (extruded)
700
2