INCH-POUND
MIL-DTL-24643/52F
1 October 2009
SUPERSEDING
MIL-DTL-24643/52E
22 August 2002
DETAIL SPECIFICATION SHEET
CABLE, ELECTRICAL, -20 °C TO +90 °C, 300 VOLTS, TYPE LSTPNW
This specification is approved for use by all Departments and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification sheet and
MIL-DTL-24643.
Construction, Non-Watertight
First
Copper conductor, coated or uncoated 22 AWG, Class K stranding.
-
Second
Separator may be used at manufacturer's option where required to provide free-stripping
-
insulation.
Third
Thermoset insulation 0.009 inch minimum average thickness. Telephone identification
-
code shall be applied by Method 3.
Fourth
Two conductors cabled together to form a pair. Maximum lay 2 inches. For
-
LSTPNW-1½ only, three conductors, one white, one black, and one red, twisted together
to form a triad having a left-hand lay length not greater than 2 inches.
Fifth
The required number of pairs (see table I), cabled together with a lay in accordance with
-
MIL-DTL-24643, paragraph 3.4.4. Cabling sequence shall be consecutive, starting with
no. 1, from the center outwards. Fillers may be used as necessary to form a firm well
rounded assembly.
Sixth
An optional binder.
-
Seventh
Cross-linked polyolefin jacket. (see table I for thickness).
-
AMSC N/A