MIL-DTL-24643/51F
TABLE I. Details.
Overall diameter
Military part no.
Number of
Type and size
min.
max.
M24643/51
conductors
(inch)
(inch)
-01UN
LSMNW-7
7
0.370
0.400
-02UN
LSMNW-10
10
0.457
0.495
-03UN
LSMNW-14
14
0.494
0.535
-04UN
LSMNW-19
19
0.545
0.590
-05UN
LSMNW-24
24
0.633
0.685
-06UN
LSMNW-30
30
0.670
0.725
-07UN
LSMNW-37
37
0.726
0.785
-08UN
LSMNW-44
44
0.823
0.890
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
7.07
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
3000
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
1000
Conductor continuity
No failure
Group A:
Visual and dimensional
No failure
Group B:
Cold bending cable
No failure
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
2