INCH-POUND
MIL-DTL-24643/37F
1 October 2009
SUPERSEDING
MIL-DTL-24643/37E
22 August 2002
DETAIL SPECIFICATION SHEET
CABLE, ELECTRICAL, -20 °C TO +90 °C, TYPE LS3U
This specification is approved for use by all Departments and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification sheet and
MIL-DTL-24643.
Construction, Non-Watertight
First
Copper conductor, coated or uncoated, 18 AWG size, Class B stranding (7 by 0.0152
-
inches).
Second
Separator may be used at manufacturer's option where required to provide free-stripping
-
insulation.
Third
Thermoset insulation. Nominal wall thickness of 0.023 inch; wall thickness may vary
-
from nominal as necessary, in order for the completed cable to meet the specified
electrical requirements. Colored insulation, one white, one black, and one red conductor
for each triad.
Fourth
Three conductors (one black, one white, and one red) cabled together with a nominal lay
-
of 3.5 inches to form a triad.
Fifth
Identification braid on each triad. Standard identification code applied by Method 4.
-
The specified number of triads (see table I) shall be cabled together in accordance with
Sixth
-
3.4.4 of MIL-DTL-24643. Cabling sequence shall be consecutive starting with no. 1
from the center outward. Fillers may be used as necessary to form a firm well-rounded
assembly.
Seventh
An optional binder.
-
Cross-linked polyolefin jacket (see table I for thickness)
Eighth
-
AMSC N/A