MIL-DTL-24643/36F
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
2000
Conductor to shield
1000
Component shield to component shield
500
Overall shield to overall shield (Type LS3SWUS only)
200
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
500
Conductor to shield
500
Component shield to component shield
100
Overall shield to overall shield (Type LS3SWUS only)
100
Conductor continuity
No failure
Shield continuity
No failure
Jacket flaws (Type LS3SWUS only)
No failure
Group A:
Visual and dimensional
No failure
Hydrostatic (open end) (leakage at 300 lb/in2, 2 hours, in3, max.)
1.0
Capacitance
Mutual capacitance, 1 kilohertz (KHz) (pF/ft, max.)
30
Capacitance unbalanced (percent max.)
10
Group B:
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Drip (95±1 °C)
Zero
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
Tensile strength (lb/in2, min.)
1300
Elongation (percent, min.)
160
Tear (lb/in thickness, min.)
35
3