MIL-DTL-24643/35D
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
7.06
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
2000
Conductor to shield
1000
Component shield to all other shields
500
Overall shield to overall shield (Type LS3SUS only)
200
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
500
Conductor to shield
500
Component shield to all other shields
100
Overall shield to overall shield (Type LS3SUS only)
100
Conductor continuity
No failure
Shield continuity
No failure
Jacket flaws (Type LS3SUS only)
No failure
Group A:
Visual and dimensional
No failure
Capacitance
Mutual capacitance, at 1 kilohertz (KHz) (pF/ft, max.)
30
Capacitance unbalance (percent max.)
10
Group B:
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
Tensile strength (lb/in2, min.)
1300