MIL-DTL-24643/23G
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
Tensile strength (lb/in2, min.)
1300
Elongation (percent, min.)
160
Tear (lb/in thickness, min.)
35
Gas flame (1 hour) (see note below)
No failure
Group C:
Physicals (aged) air oven
Jacket (cable)
Tensile strength (percent of unaged, min.)
60
Elongation (percent of unaged, min.)
60
Permanence of printing (insulation) (cycles, min.)
25
Permanence of printing (jacket) (cycles, min.)
125
Heat distortion (percent of unaged, max.)
30
Cable fill (sealant) removability
No failure
Shrinkage
No failure
Group D:
Flame propagation (cable)
No failure
NOTE: For gas flame test of LSTTSU-1½, the three connectors shall be connected to phases A, B, and C of
the power supply. For test of all other sizes, connection of conductor pairs shall be in accordance with the
following pattern:
a.
Pair #1: One conductor to phase A, one conductor to phase B
b.
Pair #2: One conductor to phase C, one conductor to phase A
c.
Pair #3: One conductor to phase B, one conductor to phase C
d.
Pair #4: One conductor to phase A, one conductor to phase B
e.
Pair #5: One conductor to phase C, one conductor to phase A
f.
Pair #6 through Pair #60: In similar sequence.
Qualification Inspection:
Qualification inspection shall include basic electricals; groups A, B, C, and D; plus the following:
Cold working (minus 20±2 °C)
No damage
Gas flame (3 hours) (see note 1)
No failure
Aging and compatibility (cable) (125±5 °C)
No failure