MIL-DTL-24643/13E
TABLE I. Details.
Overall
Jacket wall
diameter (inch)
Number of
Military part no.
thickness
Roller diameter (inch)
Type and size
min. avg.
pairs
M24643/13
(max.)
min.
max.
(inch)
(inch)
(inch)
-01UN
LSTTRS-2
2
0.050
0.629
0.680
2.0
-02UN
LSTTRS-4
4
0.050
0.685
0.740
2.2
-03UN
LSTTRS-6
6
0.050
0.814
0.880
3.0
-04UN
LSTTRS-8
8
0.050
0.916
0.990
3.5
-05UN
LSTTRS-10
10
0.050
0.999
1.080
4.0
-06UN
LSTTRS-12
12
0.070
1.017
1.100
4.0
-07UN
LSTTRS-16
16
0.070
1.100
1.190
4.5
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
11.95
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
2000
Conductor to shield
1000
Component shield to component shield
200
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
500
Conductor to shield
200
Component shield to component shield
100
Conductor continuity
No failure
Shield continuity
No failure
Group A:
Visual and dimensional
No failure
Capacitance
Mutual capacitance at 1 megahertz (MHz) (pF/ft, max.)
28
Capacitance unbalance (percent, max.)
10
Characteristic impedance at 1 MHz (ohms)
Minimum
75
2