MIL-DTL-24643/11E
TABLE I. Details.
Overall diameter
Military part no.
Type and size
Conductor size
min.
max.
M24643/11
(inch)
(inch)
-01UN
LSSSF-7
300 MCM (Class G)
1.020
1.100
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
0.0388
Voltage withstand (volts, root mean square, min.)
Conductor to ground
2500
Insulation resistance (megohms/1000 feet, min.)
Conductor to ground
100
Conductor continuity
No failure
Group A:
Visual and dimensional
No failure
Group B:
Cold bending cable at minus 30±2 °C two turns around
No damage
an 8.5" mandrel
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Drip (95±1 °C)
Zero
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
Tensile strength (lb/in2, min.)
1300
Elongation (percent, min.)
160
Tear (lb/in thickness, min.)
35
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business