MIL-DTL-24640/5E
Cable sealant removability (Type TTXSW or TTXSOW only)
No failure
Shrinkage
No failure
Surface transfer impedance (Types TTXSO or TTXSOW only)
Milliohms per meter (max.)
700
EMP response (dB, min.)
60
Group D:
Flame propagation
No failure
Qualification Inspection:
Qualification inspection shall include basic electricals; groups A, B, C, and D; plus the following:
Aging and compatibility cable
No failure
Acid gas equivalent (percent, max. failure)
Jacket
2
Fillers
2
Insulation
18
Halogen content (percent, max.)
Jacket
0.2
Fillers
0.2
Immersion (jacket)
Tensile strength (percent of unaged, min.)
50
Elongation (percent of unaged, min.)
50
Smoke index (max.)
Jacket
25
Fillers
45
Insulation
10
Toxicity index (max.)
Jacket
5
Fillers
5
Insulation
1.5
Durometer (jacket) - Type A (hardness, min.)
80
Weathering (jacket)
No failure
Fungus resistance
No failure
Abrasion resistance
No failure
5