MIL-DTL-24640/5E
Tenth
-
Optional binder tape.
Eleventh
-
Cross-linked polyolefin jacket (see table II for thickness).
NOTE: Manufacturer's identification tape or thread is required (see 3.7.3).
TABLE I. Construction details.
Cable diameter
Cable weight
Number of
Jacket thickness
(inch)
PIN M24640/5
Type number
(pounds per 1000
pairs
(inch) (min.)
feet) (max.)
(min.)
(max.)
74.3
0.361
0.335
0.038
2
TTXS-2
-01UN
115.0
0.424
0.393
0.041
4
TTXS-4
-02UN
94.8
0.400
0.380
0.038
2
TTXSW-2
-03UN
135.3
0.455
0.430
0.041
4
TTXSW-4
-04UN
TABLE II. Construction details - overall shield.
Cable diameter
Jacket
Cable weight
PIN
Type
Number
(inch)
(pounds per 1000
thickness
M24640/5
number
of pairs
feet) (max.)
(inch) (min.)
(min.)
(max.)
126.0
0.416
0.386
0.041
2
TTXSO-2
-01UO
219.0
0.546
0.506
0.044
6
TTXSO-6
-02UO
284.0
0.633
0.587
0.044
8
TTXSO-8
-03UO
322.0
0.675
0.627
0.044
10
TTXSO-10
-04UO
137.7
0.430
0.405
0.041
2
TTXSOW-2
-05UO
250.1
0.585
0.555
0.044
6
TTXSOW-6
-06UO
302.0
0.635
0.600
0.044
8
TTXSOW-8
-07UO
385.1
0.725
0.685
0.044
10
TTXSOW-10
-08UO
REQUIREMENTS:
Qualification required.
Component wire: The component wire shall be in accordance with SAE-AS81044 and shall be tested in
accordance with the following wire ratings and additional requirements.
Temperature rating
150 °C (302 °F) (max.) conductor temperature
Voltage rating
600 volts (root mean square) at sea level
Accelerated aging
Non-blocked
Oven temperature, 300±2 °C (572±3.6 °F) for 6 hours
Water-blocked
Oven temperature, 250±2 °C (482±3.6 °F) for 6 hours
Blocking
150±2 °C (302±3.6 °F)
Flammability
30 seconds (max.)
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business