MIL-DTL-24640/24E
Qualification Inspection:
Qualification inspection shall include basic electricals; groups A, B, C, and D; plus the following:
Aging and compatibility (cable)
No failure
Acid gas equivalent (percent, max.)
Jacket
2
Fillers
2
Insulation
18
Halogen content (percent, max.)
Jacket
0.2
Fillers
0.2
Immersion (jacket)
Tensile strength (percent of unaged, min.)
50
Elongation (percent of unaged, min.)
50
Smoke index (max.)
Jacket
25
Fillers
45
Insulation
10
Toxicity index (max.)
Jacket
5
Fillers
5
Insulation
1.5
Durometer (jacket) - Type A (hardness, min.)
80
Weathering (jacket)
No failure
Fungus resistance
No failure
Abrasion resistance
No failure
Gas flame (3 hour)
No failure
Component wire
No failure
UNIT ORDERING LENGTHS:
Type and size
Feet (nominal)
1½ - 15
500
TTXW-1-1/2, TTXW-3, TTXW-5, TTXW-10,
TTXW-15, TTXW-20, TTXW-30, TTXW-40,
20 - 40
250
TTXOW-1-1/2, TTXOW-3, TTXOW-5,
TTXOW-10, TTXOW-15, TTXOW-20,
TTXOW-30, TTXOW-40
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business