MIL-DTL-24640/16E
Shield to shield
100
(component shield to overall shield, Type 2XSOW only)
Conductor and shield continuity
No failure
Jacket flaws (Type 2XSOW only)
No failure
Group A:
Visual and dimensional
No failure
Capacitance
Mutual capacitance (at 1 MHz, picofarads/foot (pF/ft), max.)
60
Capacitance unbalance (percent, max.)
15
Characteristic impedance (at 1 MHz, ohms)
30 (min.), 53 (max.)
Watertightness
No failure
(see table IX of MIL-DTL-24640 for limits of water leakage)
Weight
No failure
Group B:
Cold bending
No failure
Drip
No failure
Cross-link proof test (percent, max.)
Jacket
50
Tear (lb/in thickness, min.)
35
Physicals (unaged)
Jacket
Tensile strength (lb/in2, min.)
1300
Elongation (percent, min.)
160
Attenuation (at 3 MHz, dB/100 feet, max.)
Not applicable
Gas flame (1 hour)
Not applicable
Group C:
Physicals (aged), air oven
Jacket
Tensile strength (percent of unaged, min.)
60
Elongation (percent of unaged, min.)
60
Permanence of printing (conductor insulation, cycles, min.)
Not applicable
Permanence of printing (jacket, cycles, min.)
125
Heat distortion (percent of unaged, max.)
30
Cable sealant removability
No failure