MIL-DTL-24640/16E
Cross-linked polyolefin jacket (see table III for thickness).
Eleventh
-
NOTE: Manufacturer's identification tape or thread is required (see 3.7.3).
TABLE I. Component wire details.
Watertight conductor
Finished wire
Low temp. at -40 °C
Wire
Test load life cycle
Stranding
size
accelerated aging tests
Mandrel diameter
(no. x AWG)
Test load (lbs)
(AWG)
(lbs ±3%)
(inches)
18
7 x 26
0.250
1.0
1.0
TABLE II. Construction details.
Cable diameter
Jacket
Cable weight
PIN
Number of
(inch)
Type number
thickness
(pounds per 1000
M24640/16
pairs
(inch) (min.)
feet) (max.)
(min.)
(max.)
52.9
0.258
0.240
0.034
1
2XSW-1
-01UN
175.0
0.470
0.436
0.041
3
2XSW-3
-02UN
330.0
0.617
0.573
0.044
7
2XSW-7
-03UN
TABLE III. Construction details - overall shield.
Cable
Jacket
Cable weight
diameter
PIN
Number of
Type number
thickness
(pounds per 1000
(inch)
M24640/16
pairs
(inch) (min.)
feet) (max.)
(min.)
(max.)
227.0
0.525
0.487
0.041
3
2XSOW-3
-01UO
401.0
0.656
0.608
0.044
7
2XSOW-7
-02UO
665.0
0.864
0.802
0.047
12
2XSOW-12
-03UO
950.0
1.010
0.938
0.050
19
2XSOW-19
-04UO
1442.0
1.270
1.180
0.057
30
2XSOW-30
-05UO
REQUIREMENTS:
Qualification required.
Component wire: The component wire shall be in accordance with SAE-AS81044 and shall be tested in
accordance with the following wire ratings and additional requirements.
Temperature rating
135 °C (275 °F) (max.) conductor temperature
Voltage rating
600 volts (root mean square) at sea level
Accelerated aging
Oven temperature, 250±2 °C (482±3.6 °F) for 6 hours
Low temp. cold bend
-40 °C (-40 °F) for 4 hours
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business