MIL-DTL-24640/15E
TABLE IV. Construction details - overall shield.
Jacket
Cable diameter
Cable weight
PIN
Number of
thickness
(inch)
(pounds per
Type number
M24640/15
pairs
(inch)
1000 feet)
(min.)
(max.)
(min.)
(max.)
160.0
0.437
0.405
0.041
3
2XSAOW-3
-01UO
260.0
0.550
0.510
0.044
7
2XSAOW-7
-02UO
385.0
0.681
0.631
0.044
10
2XSAOW-10
-03UO
465.0
0.743
0.689
0.047
14
2XSAOW-14
-04UO
627.0
0.817
0.757
0.047
19
2XSAOW-19
-05UO
800.0
0.952
0.884
0.047
24
2XSAOW-24
-06UO
910.0
1.02
0.941
0.050
30
2XSAOW-30
-07UO
1050.0
1.09
1.01
0.050
37
2XSAOW-37
-08UO
REQUIREMENTS:
Qualification required.
Component wire: The component wire shall be in accordance with SAE-AS81044 and shall be tested in
accordance with the following wire ratings and additional requirements.
Temperature rating
135 °C (275 °F) (max.) conductor temperature
Voltage rating
600 volts (root mean square) at sea level
Accelerated aging
Oven temperature, 250±2 °C (482±3.6 °F) for 6 hours
Low temp. cold bend
-40 °C (-40 °F) for 4 hours
Blocking
150±2 °C (302±3.6 °F)
Color
In accordance with MIL-STD-104, Class 1
Flammability
30 seconds (max.)
3.0 inches (max.)
No flaming of tissue paper
Humidity resistance
5000 megohms for 1000 feet (min.) insulation resistance after
humidity exposure
Dielectric test
Primary insulation
6.0 kilovolts (peak), 100 percent impulse test
(when tested in lieu of spark test)
Finished wire
8.0 kilovolts (peak), or 3 kHz spark test 5.5 kV, 100 percent
test
Insulation resistance
5000 megohms for 1000 feet (min.)
Life cycle
Oven temperature, 200±2 °C (392±3.6 °F) for 120 hours
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business