MIL-DTL-17/77D
REQUIREMENTS
Dimensions, configuration, and descriptions: See figure 1 and table II.
Environmental and mechanical:
Visual and mechanical examination:
Out-of-roundness: Not applicable.
Eccentricity: 10 percent, maximum.
Adhesion of conductors:
Inner conductor to core: 7 pounds, minimum; 50 pounds, maximum.
Aging stability: +98șC ± 2șC.
Stress crack resistance: Not applicable.
Outer conductor integrity: Not applicable.
Cold bend: -40șC ± 2șC.
Dimensional stability: +85°C ± 2°C.
Inner conductor from core: 0.062 inch, maximum.
Inner conductor from jacket: 0.125 inch, maximum.
Contamination: Applicable.
Bendability: Not applicable.
Flammability: Not applicable.
Weight: 12.4 pounds per 100 feet, maximum.
Electrical:
Continuity: Applicable.
Spark test: 5,000 V rms, +10%, -0%.
Voltage withstanding: 10,000 V rms, +10%, -0%.
Insulation resistance: Not applicable.
Corona extinction voltage: 5,000 V rms, minimum.
Characteristic impedance: 75 ohms ± 3.