MIL-DTL-17/209A
REQUIREMENTS:
Continuous working voltage: 7,500 V rms, maximum.
Operating frequency: 1 GHz, maximum.
Velocity of propagation: 65.9 percent, nominal.
Power ratings: See figure 2.
Operating temperature range: -40°C to +80°C, maximum.
Inner conductor properties:
DC resistance (maximum at +20°C): .027 ohms per 100 feet.
Elongation: 30 percent, minimum.
Dimensions, configuration, and descriptions: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination: Applicable.
Out-of-roundness: Not applicable.
Eccentricity: 10 percent, maximum.
Adhesion of conductors:
Inner conductor to core: 7 pounds, minimum; 100 pounds, maximum.
Aging stability: +98° ± 2°C.
Cold bend: -40°C ± 2°C.
Stress crack resistance: Not applicable.
Dimensional stability: +85° ± 2°C.
Inner conductor from core: 0.200 inch, maximum.
Inner conductor from jacket: 0.400 inch, maximum.
Contamination: Not applicable.
Flame propagation: Applicable.
Acid gas generation: 2.0 percent, maximum.
Halogen content: 0.2 percent, maximum.
Immersion test:
Tensile strength, percent of unaged minimum: 50.
Elongation, percent of unaged minimum: 50.