MIL-DTL-17/206B
REQUIREMENTS:
Continuous working voltage: 1,400 V rms, maximum.
Operating frequency: 30 GHz, maximum.
Velocity of propagation: 69.5 percent, nominal.
Power ratings: See figure 2.
Operating temperature range: -55°C to +200°C.
Inner conductor properties:
DC resistance (maximum at +20°C): 19.5 ohms per 1000 feet, maximum.
Elongation: 1 percent, minimum.
Dimensions, configuration, and descriptions: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination: Applicable.
Out-of-roundness: Not applicable.
Eccentricity: 10 percent maximum.
Adhesion of conductors:
Inner conductor to core: 4 pounds minimum, 30 pounds maximum.
Aging stability: Not applicable.
Cold bend: -55°C ± 2°C.
Stress crack resistance: ± 230°C.
Dimensional stability: +200°C ± 5°C.
Inner conductor from core: .187 inch, maximum.
Inner conductor from jacket: .312 inch, maximum.
Contamination: Not applicable.
Flame propagation: Applicable.
Acid gas generation: Not applicable.
Halogen content: Not applicable.
Immersion test: Not applicable.
Smoke index: Not applicable.