MIL-DTL-17/186C
REQUIREMENTS:
Continuous working voltage: 750 V rms, maximum.
Operating frequency: 10 MHz, maximum.
Velocity of propagation: 65.9 percent, nominal.
Operating temperature range: -30°C to +85°C.
Inner conductor properties:
DC resistance (maximum at +20°C): 1.055 ohms per 100 feet (each conductor).
Elongation: 15 percent, minimum.
Engineering notes: This cable is useful in balance cables applications. These cables were redesigned
to meet the vertical flame test.
Dimensions, configuration, and descriptions: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination: Applicable.
Out-of-roundness: Not applicable.
Eccentricity: 10 percent maximum. 1/
Adhesion of conductors:
Inner conductor to core: 2 pounds, minimum; 20 pounds, maximum.
Aging stability: +98°C ± 2°C.
Cold bend: -30°C ± 2°C.
Dimensional stability: +85°C ± 2°C
Inner conductor from core: .062 inch, maximum.
Inner conductor from jacket: .125 inch, maximum.
Contamination: Not applicable.
Flame propagation: Applicable.
Acid gas generation: 2.0 percent, maximum.
-----
1/ (TMAX-TMIN) shall be interpreted as the difference in total wall thickness measured (1) along a line
through the centers of the conductors between the edge of each conductor and the nearest surface of
the core and (2) between a line tangent to the two conductors and a parallel line tangent to the
surface of the core on both sides of the conductors. The eccentricity corresponding to the larger
measured value (TMAX-TMIN) shall be reported.