MIL-DTL-17/185C
Continuous working voltage: 750 V rms, maximum.
Operating frequency: 1 GHz, maximum.
Velocity of propagation: 83 percent, nominal.
Power ratings: See figure 2.
Operating temperature range: -30°C to +85°C.
Inner conductor properties:
DC resistance (maximum at +20°C): 4.4 ohms per 100 feet.
Elongation: 1 percent, minimum.
2
Tensile strength: 110 klbf/inch , minimum.
Engineering notes: This cable is useful in low capacitance, medium low temperature applications.
(See connector series "TNC" and "BNC" in accordance with MIL-PRF-39012.) These cables were
redesigned to meet the vertical flame test.
REQUIREMENTS:
Dimensions, configuration, and descriptions: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination: Applicable.
Out-of-roundness: Not applicable.
Eccentricity: 10 percent maximum.
Adhesion of conductors: Not applicable.
Aging stability: +98°C ± 2°C.
Dimensional stability: Not applicable.
Contamination: Not applicable.
Flame propagation: Applicable.
Acid gas generation: 2.0 percent, maximum.
Halogen content: 0.2 percent, maximum.
Immersion test:
Tensile strength, percent of unaged minimum: 50
Elongation, percent of unaged minimum: 50.
Smoke index: 25 maximum.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.