MIL-DTL-17/135E
Operating temperature range:
-40°C to +70°C (M17/135-00001 thru M17/135-00004)
-30°C to +85°C (M17/135-00005 and M17/135-00006)
Inner conductor properties:
DC resistance (maximum at 20°C): 1.62 ohms per 100 feet. (0.173 ohm per 100 feet for M17/135-
00001 and M17/135-00002.)
Elongation: 25 percent, minimum. (30 percent minimum for M17/135-00001 and M17/135-00002)
Tensile strength: Not applicable.
Engineering note: This cable useful for non-hosing low temperature applications.
REQUIREMENTS
Dimensions, configuration, and description: See figure 1 and table I.
Environmental and mechanical:
Visual and mechanical examination:
Out-of-roundness: Not applicable.
Eccentricity: 10 percent, maximum.
Adhesion of conductors:
M17/135-00001,M17/135-00003,and M17/135-00005: 7 pounds minimum, 65 pounds maximum.
M17/135-00002,M17/135-00004,and M17/135-00006: 7 pounds minimum, 50 pounds maximum
Aging stability:
+90°C ± 2°C (M17/135-00003 and M17/135-00004)
+98°C ± 2°C (M17/135-00001, M17/135-00002, M17/135-00005 and M17/135-00006)
Stress crack resistance: Not applicable.
Outer conductor integrity: Not applicable.
Cold bend:
-55°C ± 2°C (M17/135-00001 thru M17/135-00004)
-30°C ± 2°C (M17/135-00005 and M17/135-00006)
Dimensional stability: +85°C ± 2°C.
Inner conductor from core: .125 inch, maximum.
Inner conductor from jacket: .250 inch, maximum.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business