2.2 Government documents.
2.2.1 Specifications and standards and handbooks. The following specifications, standards and
handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the
issues of these documents are those cited in the solicitation or contract.
FEDERAL STANDARD
FED-STD-228
-
Cable and Wire, Insulated; Methods of Testing.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-DTL-3885
-
Cable Assemblies and Cord Assemblies, Electrical.
(Copies of these documents are available online at https://assist.daps.dla.mil/quicksearch/ or
from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia,
PA 19111-5094.)
2.3 Non-Government publications. The following documents form a part of this document to the extent
specified herein. Unless otherwise specified, the documents are the issues of the documents cited in the
solicitation or contract (see 6.2).
NCSL INTERNATIONAL
NCSL-Z540.3
-
Requirements for the Calibration of Measuring and Test
Equipment
(Copies of this document are available from https://www.ncsli.org or from NCSL International, 2995
Wilderness Place, Suite 107, Boulder, CO 80301.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a
conflict between the text of this document and the references cited herein, the text of this document takes
precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or
environmentally preferable materials should be used to the maximum extent possible, provided that the
material meets or exceeds the operational and maintenance requirements, and promotes economically
advantageous life cycle costs.
3.2 Materials. Materials shall be as specified herein. When a material is not specified, a material
shall be used that enables the insulated wire to meet the performance requirements of this specification.
3.3 Conductor. Each conductor shall be equivalent to 511 circular mils (no. 23 AWG). It shall
consist of 21 strands of no. 36 AWG tinned soft cadmium copper alloy, having a 1% nominal
content of cadmium. It shall be bunch stranded with a lay not exceeding .75 inch (19.05 mm). Prior to
stranding, the elongation of individual tinned soft cadmium copper alloy strands shall be not less than
10%, and the tensile strength shall not exceed 55,000 psi. Subsequent to stranding, and prior to