MIL-DTL-17/179B
Power rating: See figure 2.
Operating temperature range: -55°C to +150°C.
Inner conductor properties:
DC resistance (maximum at +20°C): 24.45 ohms per 100 feet.
Elongation: 10 percent, minimum.
2
Tensile strength: 50klbf/inch minimum.
Engineering note: This cable is useful on shield critical medium high temperature applications.
(See connector series "TRB" and "TRT" in accordance with MIL-PRF-49142,
including related specification sheets and MIL-STD-348.)
REQUIREMENTS
Dimensions, configuration, and description: See figure 1 and table I.
Environmental and mechanical: Applicable.
Visual and mechanical examination:
Out-of-roundness: Not applicable.
Eccentricity: 10 percent, maximum.
Adhesion of conductors:
Inner conductor to core: 1.5 pounds, minimum; 4 pounds, maximum.
Aging stability: Not applicable.
Stress crack resistance: +230ºC ± 5ºC.
(Note: Requirement is prior to adding shields over jacket.)
Outer conductor integrity: Not applicable.
Cold bend: -55°C ± 2°C.
Dimensional stability: +200ºC ± 5ºC.
(Note: Requirement is prior to adding shields over jacket.)
Inner conductor from core: .187 inch, maximum.
Inner conductor from any jacket: .250 inch, maximum.
Contamination: Not applicable.
Bendability: Not applicable.
Flammability: Applicable.
Weight: 36.5 pounds per 1,000 feet, maximum.
3