FED-STD-228A
where:
D1=the diameter over the serving at the point measured, inches.
D2=the diameter over the core at the point measured, inches.
5.2 Unless otherwise specified in the detail specification, two specimens, one from each end of the
inspection unit, shall be tested.
5.3 The thickness of the serving of the inspection unit shall be the average of the results obtained from
the specimens tested.
5.4 The thickness of the serving of the inspection unit shall be recorded to the nearest mil or 0.0001 inch.