FED-STD-228A
where:
C=the capacitance in microfarads of the immersed 10 feet of the specimen
D=the diameter over the insulation, inches
d=the diameter over the conductor, inch
5.2 Unless otherwise specified in the detail specification, one specimen from each inspection unit shall
be tested.
5.3 The capacitance change of the insulation of the inspection unit shall be the result obtained from the
specimen tested.
5.3.1 When more than one specimen is tested from each inspection unit, the capacitance change of the
insulation of the inspection unit shall be the average of the results obtained from the specimens tested.
5.4 The capacitance change of the insulation of the inspection unit shall be recorded to the nearest 0.1
percent.
5.5 The temperature and time of immersion shall be recorded.