MIL-DTL-24643C
6.7 Definitions. For the purpose of the conformance inspection, the sampling terms specified in 6.7.1 through
6.7.4 will apply.
6.7.1 Defective unit. A defective unit is a unit of product from which a specimen that failed to meet one or
more requirements was taken.
6.7.2 Sample. A sample is one unit of product selected from an inspection lot.
6.7.3 Specimen. A specimen is an individual length of cable or an individual length of a part of cable which
has been taken from a sample.
6.7.4 Unit of product. A unit of product is the unit ordering length as specified on the specification sheet,
except that when the unit ordering length is 500 feet, two such lengths will constitute a unit of product. Random and
remnant lengths or special order lengths may be added together to equal a unit ordering length. Length tolerances as
given for standard lengths will apply (see 6.2.4).
a. For basic electrical test purposes (see table VIII), a unit of product will be defined as an electrically
continuous splice free length. This is to allow for longer production lengths to be tested electrically prior to
preparation for shipment.
b. Lengths longer than the unit ordering lengths (see 3.1) may be supplied when the purchaser and
manufacturer agree. These lengths will be as specified in 6.7.4.a.
6.8 Subject term (key word) listing.
Armor
Flame propagation
Toxicity index
Water-block
6.9 Changes from previous issue. Marginal notations are not used in this revision to identify changes with
respect to the previous issue due to the extent of the changes.