MIL-DTL-915/9F
Group A:
Visual and dimensional ...................................................................... No failure
Bending endurance at 25°C, (performed on one specimen from
each lot); 14-inch maximum diameter mandrel, flatwise,
cycles, minimum ................................................................................. 100,000
Group B:
Physicals (unaged)
Insulation (conductor)
Tensile strength - lbf/in2, minimum .................................... 600
Elongation - percent, minimum .......................................... 300
Jacket (cable)
Tensile strength - lbf/in2, minimum ................................... 1800
Elongation - percent, minimum .......................................... 300
Group C:
Flammability inches, maximum..................................................................... 2
Physicals (aged)
Insulation (conductor)
Air Oven
Tensile strength - percent of unaged, minimum..........50
Elongation - percent of unaged, minimum..................50
Jacket (cable)
Air Oven
Tensile strength lbf/in2, minimum............................50
Elongation- percent, minimum....................................50
Hot oil immersion
Tensile strength - percent of unaged, minimum..........60
Elongation - percent of unaged, minimum..................60
Permanence of printing (jacket) - cycles, minimum ......................................250
Cable filler removability ...................................................................... No failure
QUALIFICATION INSPECTION:
Qualification inspection shall include basic electrical, plus all of groups A, B, and C.
UNIT ORDERING LENGTH:
500 feet (nominal)