MIL-DTL-915/81A
Cable jacket
Tensile strength - lbf/in2, minimum .............................................. 1800
Elongation - percent, minimum ...................................................... 500
Group C:
Physicals (aged)
Insulation
Air oven (168 hours at 180°C)
Tensile strength - percent of unaged, minimum...................90
Elongation - percent of unaged, minimum...........................90
Insulation jacket
Air oven (96 hours at 100 + 2°C)
Elongation - percent of original............................................60
Cable jacket
Air oven (96 hours at 100 + 20°C)
This test shall be in accordance with
MIL-DTL-915.......................................................... No failure
Environmental stress crack
This test shall be performed in accordance with
MIL-DTL-915.......................................................... No failure
Mutual capacitance - pF/ft at 2 kHz, maximum............................................25
QUALIFICATION INSPECTION:
Qualification inspection shall include basic electrical, plus all of groups A, B and C.
UNIT ORDERING LENGTH:
1000 feet (nominal).
PART OR IDENTIFYING NUMBER (PIN): The PIN consists of the letter M, the general
specification number along with the specification sheet, and a dash number representing type and
size. Refer to MIL-DTL-915 for an example.
M
915
/81-
X-X
Specification
Specification
Type and Size
Prefix for
Military
Number
Sheet
Number
Specification
CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to identify
changes with respect to the previous issue due to the extent of the changes.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business