MIL-DTL-915/67D
Conductor to conductor............................................................................................150
Conductor to shield .................................................................................................. 150
Shield to shield ......................................................................................................... 100
Group A:
Visual and dimensional .......................................................................................................... No failure
Characteristic impedance (size 22 conductors only) -at l MHz; ohms ........................................55 ± 5
Capacitance (size 22 conductors only) -at l kHz; pF/ft, maximum....................................................27
Group B:
Cold bending, cable - at 0 ± 2°C; over 18 inch maximum diameter mandrel .................... No damage
Physicals (unaged)
Insulation (polyvinyl chloride only)
Tensile strength - lbf/in2, minimum ....................................................................... 1800
Elongation - percent, minimum ............................................................................... 100
Jacket (cable)
Tensile strength - lbf/in2, minimum ....................................................................... 1800
Elongation - percent, minimum ............................................................................... 300
Set - inch, maximum .............................................................................................30/64
Group C:
Flammability - inches, maximum ......................................................................................................... 2
Physicals (aged)
Insulation (polyvinyl chloride only)
Air oven
Elongation - percent of unaged, minimum....................................................90
Jacket (cable)
Air pressure heat
Tensile strength - percent of unaged, minimum............................................65
Elongation - percent of unaged, minimum....................................................65
Hot oil immersion
Tensile strength - percent of unaged, minimum............................................65
Elongation - percent of unaged, minimum....................................................65
Permanence of printing (jacket) - cycles, minimum ........................................................................ 250
Shield-conformance to material coverage and construction ................................................ No failure
QUALIFICATION INSPECTION:
Qualification inspection shall include basic electrical, plus all of groups A, B and C.
UNIT ORDERING LENGTH: 500 feet (nominal).
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business