INCH-POUND
MIL-DTL-915/66D
22 August 2002
SUPERSEDING
MIL-C-915/66C
29 September 1989
DETAIL SPECIFICATION SHEET
CABLE, SPECIAL PURPOSE, ELECTRICAL, 59-CONDUCTOR,
FOR OUTBOARD USE ONLY (NOT FOR INBOARD USE), TYPE MSPW
This specification is approved for use by all Departments and Agencies of the
Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification
sheet and the issue of MIL-DTL-915 listed in that issue of the Department of Defense Index of
Specifications and Standards (DoDISS) specified in the solicitation.
REQUIREMENTS:
Qualification required.
Construction (watertight)
Conductor size 22-7 (16 required):
First
- Copper conductor, in accordance with ASTM B 286, size 22-7, tin coated.
Second - Fluoropolymer insulation, nominal thickness 0.044 inch. (Taped insulation
may be used.)
Third
- Braided shield of AWG No. 34 or No. 36 copper. Minimum coverage 85
percent; braid angle 30 to 35 degrees.
Fourth - Shield insulation of one polyester tape, in accordance with NEMA FI 4,
opaque white, with a jacket of transparent polyamide in accordance with
ASTM D 4066. Nominal thickness 0.003.
- Alternate shield insulation of two polyester tapes, in accordance with NEMA
FI 4, sealed. Inner tape opaque white; outer tape yellow.
For either type of shield insulation, use standard identification code applied by
method 2, on the inner tape, using numbers 30 through 45.
AMSC N/A
1 of 5
FSC 6145
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business