INCH-POUND
MIL-DTL-915/47D
22 August 2002
SUPERSEDING
MIL-C-915/47C
29 September 1989
DETAIL SPECIFICATION SHEET
CABLE, SPECIAL PURPOSE, ELECTRICAL, FOR OUTBOARD USE ONLY
(NOT FOR INBOARD USE), TYPE 1SWF
This specification is approved for use by all Departments and Agencies of the Department
of Defense.
The requirements for acquiring the product described herein shall consist of this specification
sheet and the issue of MIL-DTL-915 listed in that issue of the Department of Defense Index of
Specifications and Standards (DoDISS) specified in the solicitation.
REQUIREMENTS:
Qualification required.
Construction (watertight)
First
- Copper, conductor, in accordance with ASTM B 286, size 22-7, uncoated.
Second - Polyethylene insulation, natural, type II, class L, grade 3 in accordance with
L-P-390. Nominal thickness 0.045 inch.
Third
- Braided shield of AWG No. 34 or No. 36 uncoated copper. Braid angle of 30
to 35 degrees; minimum coverage of 85 percent.
Fourth - Shield insulation of one polyester tape, in accordance with NEMA FI 4, plus a
jacket of clear polyamide in accordance with ASTM D 4066. Nominal
thickness of 0.003 inch. Standard identification code applied by method 2.
- Alternate shield insulation of two polyester tapes, in accordance with NEMA
FI 4, sealed. Standard identification code applied by method 2 on inner tape.
Fifth
- Two conductors, one black and one white, cabled with a lay not greater than 3
inches. Nonfibrous fillers shall be used.
Sixth
- Binder tape applied helically with overlap.
Seventh - Arctic type polychloroprene jacket (black). Cable jacket thickness 0.100-inch
maximum. Cable surface marking required.
AMSC N/A
1 of 3
FSC 6145
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.