MIL-DTL-55040E
4.3 Requirements cross-reference matrix. Table I provides a cross-reference matrix of section 3
requirements tested or verified below.
TABLE I. Requirements cross-reference matrix.
Requirement
Verification
Requirement
Verification
3.1.1
3.1.2
3.1.3
4.4 Inspection conditions. Unless otherwise specified (see 6.2), all inspections shall be
conducted under the following ambient conditions: 77±18 °F, site pressure, and site uncontrolled relative
humidity.
4.5 Individual inspection. Unless otherwise specified (see 6.2), each cable shall be inspected in
accordance with the individual inspections specified in table II.
TABLE II. Conformance inspections.
Conformance inspections
Inspection
Requirement
Verification
Individual Sampling
Periodic
Visual & Mechanical
3.1, 3.1.1
Material
X
3.1.2, 3.1.3
Color
X
Dimensions
X
Construction
X
Workmanship
X
Material tests
Tensile strength
3.1.1, 3.1.3
X
Elongation
3.1.1, 3.1.3
X
Set
3.1.1
X
Accelerated aging
3.1.1, 3.1.3
X
Performance tests
Conditioning
X
Life cycle
X
Extended length
X
Set
X
Static load
X
Retraction at low
X
temperature
Voltage withstand
X
Insulation resistance
X
4