MIL-DTL-27072/94D
REQUIREMENTS:
Design and construction:
See figure 1
Number of conductors:
1
200 °C
Temperature rating:
Components:
Basic wire:
Either NEMA-HP3 or SAE-AS22759 (see table I)
Conductor:
Silver-coated copper
Primary insulation:
Polytetrafluoroethylene
Colors:
White
Jacket over insulation:
Not applicable
Filler:
Not applicable
Cabling:
Not applicable
Binder tape material:
Not applicable
Insulation:
Polytetrafluoroethylene extruded
Marking tape:
Marking tape shall be placed under the sheath or shield
Shield:
Material:
Silver-coated copper
Gauge:
38 AWG
Braid angle:
20 to 40 degrees
Jacket under shield:
Not applicable
Sheath:
Material:
Polytetrafluoroethylene
Wall thickness:
Not applicable
Tensile strength:
In accordance with MIL-DTL-27072
Ultimate elongation:
In accordance with MIL-DTL-27072
Accelerated aging:
In accordance with MIL-DTL-27072
Color:
See MIL-DTL-27072
Finished cable:
See table I
Cold bend:
Mandrel size in accordance with MIL-DTL-27072
Dielectric withstanding voltage:
2,000 V rms
Conductor resistance:
In accordance with basic wire specification