MIL-DTL-27072/89D
REQUIREMENTS:
Design and construction:
See figure 1
Number or conductors:
3
200°C
Temperature rating:
Components:
Basic wire:
Either NEMA- HP3 or SAE-AS22759 (See table I)
Conductor:
Silver-coated copper
Primary insulation:
Polytetrafluoroethylene
Colors:
White
Black
Red
Jacket over insulation:
Not applicable
Filler:
Not applicable
Cabling:
Not applicable
Binder tape material:
Not applicable
Marking tape:
Marking tape shall be placed under the sheath or shield
Shield:
Material:
Silver-coated copper
Construction:
See table I
Braid angle:
Braid 20 to 40 degrees
Jacket undershield:
Not applicable
Sheath:
Material:
Polytetrafluoroethylene
.011 ± .003 inch (.28 ±.08 mm)
Wall thickness:
Tensile strength:
In accordance with MIL-DTL-27072
Ultimate elongation:
In accordance with MIL-DTL-27072
Accelerated aging:
Not applicable
Color:
See MIL-DTL-27072
Surface resistance (sheath): When tested in accordance with method 6041 of FED-STD-228, the initial
surface resistance shall be not less than 5 megohms. The final surface resistance shall be within 50
percent of the initial surface resistance. (NOTE: The specimen for this inspection test shall not be
subjected to any other electrical tests.)
Finished cable:
See table I
Cold bend:
Mandrel size in accordance with MIL-DTL-27072
Dielectric withstanding voltage:
2,000 V rms
Conductor resistance:
In accordance with basic wire specification