MIL-DTL-24643/54F
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
1.72
Voltage withstand (volts, root mean square, min.)
Conductor to conductor
4000
Insulation resistance (megohms/1000 feet, min.)
Conductor to conductor
4200
Conductor continuity
No failure
Group A:
Visual and dimensional
No failure
Group B:
Cold bending cable
No failure
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
Tensile strength (lb/in2, min.)
1300
Elongation (percent, min.)
160
Tear (lb/in thickness, min.)
35
Group C:
Physicals (aged) air oven
Insulation (extruded)
Tensile strength (percent of unaged, min.)
75
Elongation (percent of unaged, min.)
75
Jacket (cable)
Tensile strength (percent of unaged, min.)
60
Elongation (percent of unaged, min.)
60