INCH-POUND
MIL-DTL-24643/5G
1 October 2009
SUPERSEDING
MIL-DTL-24643/5F
22 August 2002
DETAIL SPECIFICATION SHEET
CABLE, ELECTRICAL, -20 °C TO +90 °C, 600 VOLTS, TYPE LSMDU
This specification is approved for use by all Departments and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification sheet and
MIL-DTL-24643.
Construction, Watertight
First
Copper conductor, coated or uncoated (see table I for size).
-
Second
Separator may be used at manufacturer's option where required to provide free-stripping
-
insulation.
Thermoset insulation (see table I for wall thickness). Standard identification code
Third
-
applied by Method 1 or Method 3. If identification Method 1 is used, insulation color
shall be black.
Fourth
Nineteen conductors cabled together in accordance with 3.4.4 of MIL-DTL-24643.
-
Cabling sequence to be consecutive, starting with no. 1 from the center outward. Fillers
may be used as necessary to form a firm well-rounded assembly.
Fifth
An optional binder.
-
Cross-linked polyolefin jacket (see table I for thickness).
Sixth
-
AMSC N/A
FSC 6145
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business