MIL-DTL-24643/49F
TABLE I. Details.
Overall diameter
Insulation
Cable jacket
Military part no.
AWG conductor
thickness min.
thickness min.
Type and size
min.
max.
M24643/49
size
avg. (inch)
avg. (inch)
(inch)
(inch)
-01UN
LSTNW-3
16 (Class B)
0.030
0.040
0.380
0.411
-02UN
LSTNW-4
14 (Class B)
0.030
0.040
0.415
0.449
-03UN
LSTNW-9
10 (Class B)
0.030
0.050
0.578
0.625
-04UN
LSTNW-14
9 (Class B)
0.045
0.050
0.620
0.670
-05UN
LSTNW-23
7 (Class B)
0.045
0.055
0.703
0.760
-06UN
LSTNW-50
3 (Class C)
0.045
0.060
0.869
0.969
-07UN
LSTNW-75
1 (Class C)
0.055
0.070
1.048
1.134
-08UN
LSTNW-100
0 (Class D)
0.055
0.075
1.171
1.266
-09UN
LSTNW-150
000 (Class D)
0.055
0.075
1.401
1.515
-10UN
LSTNW-200
0000 (Class D)
0.055
.075
1.555
1.669
-11UN
LSTNW-300
300 MCM (Class D)
0.055
.090
1.843
1.957
-12UN
LSTNW-400
400 (127) Navy std
0.055
.090
2.089
2.203
-13UN
LSTNW-30
30 (19)
0.045
0.055
0.725
0.775
TABLE II. Electrical details.
Insulation
Accelerated service
Conductor
Voltage withstand
Type and size
resistance
loading current
resistance (ohms)
min. (volts)
(megohms)
(amperes)
LSTNW-3
4.3
6000
4000
NA
LSTNW-4
2.68
5000
4000
NA
LSTNW-9
1.08
3800
4000
NA
LSTNW-14
0.859
4400
5500
90
LSTNW-23
0.543
3700
5500
115
LSTNW-30
0.26
3000
5500
145
LSTNW-50
0.21
2600
5500
185
LSTNW-75
0.134
2600
7000
250
LSTNW-100
0.106
2400
7000
295
LSTNW-150
0.0674
1800
7000
400
LSTNW-200
0.053
1500
7000
525
LSTNW-300
0.0377
1200
7000
600
LSTNW-400
0.0273
1000
7000
800
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business