MIL-DTL-24643/48F
TABLE I. Details.
Overall diameter
Insulation
Cable jacket
Military part no.
thickness min.
thickness (min.
Type and size
AWG conductor size
min.
max.
M24643/48
avg. (inch)
avg.) (inch)
(inch)
(inch)
-01UN
LSDNW-3
16 (Class B)
0.030
0.040
0.361
0.390
-02UN
LSDNW-4
14 (Class B)
0.030
0.040
0.398
0.430
-03UN
LSDNW-9
10 (Class B)
0.030
0.040
0.504
0.545
-04UN
LSDNW-14
9 (Class B)
0.045
0.040
0.564
0.610
-05UN
LSDNW-23
7 (Class B)
0.045
0.045
0.638
0.690
-06UN
LSDNW-50
3 (Class C)
0.045
0.050
0.842
0.910
-07UN
LSDNW-75
1 (Class C)
0.055
0.055
1.000
1.080
-08UN
LSDNW-100
0 (Class D)
0.055
0.055
1.082
1.170
-09UN
LSDNW-200
0000(Class D)
0.055
0.070
1.498
1.413
-10UN
LSDNW-300
300MCM (Class D)
0.055
0.085
1.756
1.671
-11UN
LSDNW-400
400 (127) (Navy std)
0.055
0.085
1.984
1.899
TABLE II. Electrical details.
Accelerated service
Insulation
Voltage withstand
Conductor
loading current
resistance
Type and size
min. (volts)
resistance (ohms)
(amperes)
(megohms)
LSDNW-3
4.3
6000
4000
NA
LSDNW-4
2.68
5000
4000
NA
LSDNW-9
1.08
3800
4000
NA
LSDNW-14
0.86
4400
5500
100
LSDNW-23
0.54
3700
5500
130
LSDNW-50
0.21
2600
5500
215
LSDNW-75
0.13
2600
7000
285
LSDNW-100
0.11
2400
7000
335
LSDNW-200
0.053
2400
7000
525
LSDNW-300
0.0377
2400
7000
700
LSDNW-400
0.0273
2400
7000
835