MIL-DTL-24643/47D
TABLE I. Details.
Overall diameter
Military part
Number of
Type and size
Min.
Max.
no. M24643/47
shielded singles
(inch)
(inch)
-01UN
LS1SMWU-70
70
1.465
1.555
REQUIREMENTS:
Qualification required.
INSPECTION:
Basic Electricals:
Conductor resistance (ohms/1000 feet at 25 °C, max.)
17.71
Voltage withstand (volts, root mean square, min.)
Conductor to shield
5000
Component shield to component shield
500
Insulation resistance (megohms/1000 feet, min.)
Conductor to shield
500
Component shield to component shield
100
Conductor continuity
No failure
Shield continuity
No failure
Group A:
Visual and dimensional
No failure
Capacitance (mutual), at1 kilohertz (KHz) (pF/ft, max.)
35
Watertightness (see MIL-DTL-24643 for limits of water leakage)
No failure
Group B:
Cold bending cable
No failure
Thermoset proof test (percent, max.)
Insulation
50
Jacket (when tested at 200 °C)
50
Drip (95±1°C)
Zero
Physicals (unaged)
Insulation (extruded)
Tensile strength (lb/in2, min.)
700
Elongation (percent, min.)
150
Jacket (cable)
2