INCH-POUND
MIL-DTL-24643/45F
1 October 2009
SUPERSEDING
MIL-DTL-24643/45E
22 August 2002
DETAIL SPECIFICATION SHEET
CABLE, ELECTRICAL, -20 °C TO +90 °C, TYPE LS2U
This specification is approved for use by all Departments and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification sheet and
MIL-DTL-24643.
Construction, Non-Watertight
First
Copper conductor, tin-coated, ASTM B286, 26 AWG 7 strands.
-
Second
Separator may be used at manufacturer's option where required to provide free-stripping
-
insulation.
Third
Thermoset insulation. Nominal wall thickness of 0.015 inch: wall thickness may vary
-
from nominal as necessary, in order for completed cable to meet the specified electrical
requirements. Telephone identification code shall be applied by Method 3.
Fourth
Two conductors cabled together with a maximum lay of 1½ inches to form a pair.
-
The specified number of pairs (see table I) shall be cabled together with a lay in
Fifth
-
accordance with 3.4.4 of MIL-DTL-24643. Cabling sequence shall be consecutive,
starting with no. 1, from the center outward. Fillers may be used as necessary to form a
firm well-rounded assembly.
Sixth
An optional binder.
-
Seventh
Braided shield of tin-coated copper.
-
Eighth
An optional binder.
-
Cross-linked polyolefin jacket (see table I for thickness).
Ninth
-
AMSC N/A
FSC 6145
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business