INCH-POUND
MIL-DTL-24643/41D
1 October 2009
SUPERSEDING
MIL-DTL-24643/41C
22 August 2002
DETAIL SPECIFICATION SHEET
CABLE, ELECTRICAL, -20 °C TO +90 °C, TYPE LS1SAU
This specification is approved for use by all Departments and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of this specification sheet and
MIL-DTL-24643.
Construction, Non-Watertight
First
Copper conductor, coated or uncoated, ASTM B286, Size 20 7 strands.
-
Second
Separator may be used at manufacturer's option where required to provide free-stripping
-
insulation.
Third
Thermoset insulation. Nominal wall thickness of 0.015 inch. Wall thickness may vary
-
from nominal as necessary in order for completed cable to meet the specified electrical
requirements.
Fourth
Braided shield of 34 or 36AWG, coated or uncoated copper. Braid angle of 30 to 35
-
degrees; minimum coverage of 85 percent.
Fifth
Shield insulation of two polyester tapes, outer tape sealed. An alternate shield insulation
-
may consist of one polyester tape, plus an extruded jacket of a suitable transparent
material, minimum average thickness of the transparent material 0.003 inch. The
standard identification code shall be applied by Method 2.
The specified number of singles (see table I) shall be cabled together in accordance with
Sixth
-
3.4.4 of MIL-DTL-24643. Cabling sequence shall be consecutive starting with no. 1
from the center outward. Fillers may be used as necessary to form a firm well-rounded
assembly.
Seventh
An optional binder.
-
Eighth
Cross-linked polyolefin jacket. Minimum average wall thickness of 0.063 inch.
-
AMSC N/A
FSC 6145
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business