MIL-DTL-24643/39F
Tear (lb/in thickness, min.)
35
Cold bending cable
No failure
Group C:
Physicals (aged) air oven
Insulation (extruded)
Tensile strength (percent of unaged, min.)
75
Elongation (percent of unaged, min.)
75
Jacket (cable)
Tensile strength (percent of unaged, min.)
60
Elongation (percent of unaged, min.)
60
Permanence of printing (jacket) (cycles, min.)
125
Heat distortion (percent of unaged, max.)
30
Shrinkage
No failure
Shield (conformance to material, construction and coverage)
No failure
Group D:
Flame propagation (cable)
No failure
Qualification Inspection:
Qualification inspection shall include basic electricals; groups A, B, C, and D; plus the following:
Aging and compatibility (cable) (125±5 °C)
No failure
Abrasion resistance (jacket) (scrapes, min.)
75
Acid gas equivalent (percent, max.)
Jacket
2
Fillers
2
Insulation
18
Shield insulation
2
Halogen content (percent, max.)
Jacket
0.2
Fillers
0.2
Insulation
0.2
Immersion (jacket)
Tensile strength (percent of unaged, min.)
50
Elongation (percent of unaged, min.)
50
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business